If you use the 'Stop Condition' function in the Parameter tab of the Dynamic/Kinematic Analysis dialog box, the analysis can be stopped when the specified expression is satisfied.
Using this Stop Condition function and the Endless Simulation option added to RecurDyn 2023, the simulation does not end until certain conditions are satisfied.
1. First, uncheck the End Time option in the General tab of the Dynamic/Kinematic Analysis dialog box to disable it.
- For more detailed information about End Time: How to simulate infinitely without termination
2. Activate the Stop Condition in the Parameter tab of the Dynamic/Kinematic Analysis dialog box, and define the condition to stop the simulation as an Expression function.
3. Click the Simulate button to perform the analysis.